HAZOP guide words: the complete list with parameters and examples

Guide words are the engine of a HAZOP study. Applied to process parameters, they turn a design intent into a structured list of possible deviations. This reference covers every guide word in IEC 61882, the parameters they are applied to, a guide word × parameter matrix, guide words for procedures, and the German PAAG equivalents.

Updated · Reading time 8 min · HAIZOP editorial team

The HAZOP guide words at a glance

  • Seven basic guide words: NO or NOT, MORE, LESS, AS WELL AS, PART OF, REVERSE, OTHER THAN.
  • Time and sequence (IEC 61882): EARLY, LATE, BEFORE, AFTER.
  • Deviation = guide word × parameter, e.g. MORE + pressure = high pressure, REVERSE + flow = reverse flow.
  • Further guide words are allowed if they are defined before the study starts. Not every combination is meaningful – the team pursues the credible ones.

The basic HAZOP guide words

Guide words in IEC 61882
Guide wordMeaningExample deviations
NO or NOTComplete negation of the design intentNo flow, no agitation, no cooling
MOREQuantitative increaseMore flow, higher pressure, higher temperature, higher level
LESSQuantitative decreaseLess flow, lower pressure, lower level, lower temperature
AS WELL ASQualitative modification or increase – something happens in additionContamination, second phase, external leak, corrosion products
PART OFQualitative modification or decrease – only part of the intent is achievedMissing component, wrong concentration, incomplete reaction
REVERSELogical opposite of the design intentReverse flow, reverse reaction
OTHER THANComplete substitutionWrong substance, wrong destination, different operating mode

In practice, teams often use combined forms such as “high flow”, “low level” or “no flow”. They are simply a guide word applied to a parameter (MORE + flow, LESS + level, NO + flow).

Guide words for time and sequence

Time and sequence guide words in IEC 61882
Guide wordMeaningExample deviations
EARLYRelative to clock time: too earlyValve opens too early, feed starts before the reactor is at temperature
LATERelative to clock time: too lateCooling starts too late, alarm acknowledged too late
BEFORERelative to order: a step happens before it shouldHeating starts before the vessel is filled
AFTERRelative to order: a step happens after it shouldVent valve closed after purging has already started

These guide words matter most for batch processes, start-up and shutdown and for procedures. In the classic German PAAG method, deviations in time fall under OTHER THAN and a reversed sequence under REVERSE.

Parameters: what the guide words are applied to

The design intent of a node is expressed through parameters. Typical parameters in process plants are flow, pressure, temperature, level and composition, plus – depending on the plant – pH, reaction, phase, viscosity, agitation, time, sequence, utilities, maintenance and sampling.

Guide word × parameter matrix (examples)
ParameterNO / NOTMORELESSREVERSEAS WELL ASOTHER THAN
FlowNo flowHigh flowLow flowReverse flowContaminated flowWrong substance
Pressure–High pressureLow pressure, vacuum–––
Temperature–High temperatureLow temperature–––
LevelEmpty vesselHigh level, overfillLow level––Wrong vessel filled
CompositionComponent missingHigh concentrationLow concentration–Impurity, water, airWrong material
ReactionNo reactionFaster reactionSlower reactionReverse reactionSide reactionDifferent reaction

Not every cell yields a credible deviation. Many studies pre-select the meaningful combinations for each node; the facilitator makes sure that nothing relevant is skipped.

A practical HAZOP deviation list

Many companies keep a standard list of deviations as a starting point for process nodes:

  • No, high, low and reverse flow
  • High and low pressure, vacuum
  • High and low temperature
  • High and low level, overfill
  • Contamination, wrong composition, wrong substance
  • Loss of containment: leaks, ruptures, corrosion, erosion
  • Loss of utilities: power, cooling water, instrument air, nitrogen, steam
  • Start-up, shutdown and emergency shutdown
  • Maintenance, isolation, draining and purging
  • Sampling and manual operations

Guide words for procedures and human error

HAZOP can also examine operating procedures, where each node is a step. IEC 61882:2016 includes an improved case study of a procedural HAZOP. The guide words are then applied to actions:

Guide words applied to a procedure step
Guide wordDeviation of a step
NO / NOTStep omitted
MORE / LESSToo much or too little of an action, e.g. valve opened too far
AS WELL ASAn additional, unintended action
PART OFStep only partly carried out
REVERSEOpposite action, e.g. valve closed instead of opened
OTHER THANWrong action, wrong equipment, wrong material
EARLY / LATEStep carried out too early or too late
BEFORE / AFTERSteps carried out in the wrong order

German guide words (PAAG)

In Germany HAZOP is also known as the PAAG method. Its seven classic guide words (Leitworte) correspond to the basic IEC guide words:

IEC 61882German (PAAG)
NO / NOTNEIN / NICHT
MOREMEHR
LESSWENIGER
AS WELL ASSOWOHL ALS AUCH
PART OFTEILWEISE
REVERSEUMKEHRUNG
OTHER THANANDERS ALS

Tips for applying guide words

  • Agree the set in advance: define the guide words, including any additional ones, before the first session.
  • Choose an order and keep it: parameter first or guide word first – both are allowed in IEC 61882; consistency helps the team.
  • Pre-select combinations: skip combinations that make no physical sense instead of discussing them.
  • Write a precise design intent: without design values, MORE and LESS cannot be applied meaningfully.
  • Close with overview topics: at the end of a P&ID, many teams review topics that apply to the whole drawing, such as maintenance, utilities failure, start-up and shutdown or sampling.

Our free HAZOP template includes the guide words as a drop-down list and a guide word sheet. Worked deviations for six process units are in HAZOP examples.

Frequently asked questions

What are the seven HAZOP guide words?

NO or NOT, MORE, LESS, AS WELL AS, PART OF, REVERSE and OTHER THAN. IEC 61882 adds EARLY, LATE, BEFORE and AFTER for time and sequence.

What is the difference between a guide word and a deviation?

A guide word is a prompt such as MORE. A deviation is the guide word applied to a parameter, such as more flow or higher pressure.

Can I add my own guide words?

Yes. IEC 61882 allows further guide words if they are defined before the study begins.

Are HIGH and LOW guide words?

In practice they are used as shorthand for MORE and LESS combined with a parameter, for example high flow or low level.

Which guide words are used for procedures?

The same set, applied to steps: NO (step omitted), MORE or LESS, AS WELL AS (extra action), PART OF (incomplete step), REVERSE (opposite action), OTHER THAN (wrong action), EARLY or LATE and BEFORE or AFTER (wrong order).